AxonPulse
Battery Health Report · by Axonetics
Report Date
28 April 2026
BY
2023 BYD Atto 3
Extended Range · Boulder Grey
VIN: LGXCE4CB0P1234567
Licence Plate: EV-0091
Owner: Li Wei
Chemistry: LFP Battery
Cell Count: 161 cells
Nominal Capacity: 60.48 kWh
97.2%
State of Health
Measured Capacity
58.8 kWh
Degradation
2.8% from new
Annual Loss Rate
1.58%/yr
Years to 80% SOH
10.9 yrs
Confidence
medium
Method
cell voltage
SOH History — Last 14 Readings
#DateSOH %OdometerSOC %Capacity (kWh)Method
115 Oct 202499.7%500 km100%60.3cell voltage
22 Dec 202499.5%1,800 km98%60.2cell voltage
319 Jan 202599.3%3,500 km100%60.1cell voltage
48 Mar 202599.1%5,200 km95%59.9cell voltage
525 Apr 202598.9%7,000 km100%59.8cell voltage
612 June 202598.7%8,800 km97%59.7cell voltage
730 July 202598.5%10,500 km100%59.6cell voltage
84 Sept 202598.3%12,000 km99%59.5cell voltage
910 Oct 202598.2%13,200 km100%59.4cell voltage
1015 Nov 202598.0%14,400 km96%59.3cell voltage
1121 Dec 202597.8%15,500 km100%59.1cell voltage
1226 Jan 202697.6%16,400 km98%59.0cell voltage
133 Mar 202697.4%17,200 km100%58.9cell voltage
148 Apr 202697.2%18,000 km99%58.8cell voltage
Cell Data — Last Reading (08/04/2026)
Min Voltage
3.579 V
Max Voltage
3.639 V
Mean Voltage
3.609 V
Voltage Spread
15.0 mV
Recommendations
1
Battery health is excellent. Continue normal charging habits.
2
LFP battery: charging to 100% regularly is recommended (unlike NMC). Full charges help balance cells.
Generated by AxonPulse · axonetics.com.au
Report generated on 28 April 2026 · Confidential